Strain Gage Transducers Instruments Special Instruments Strain gage

 



 

ZF Series
High Temperature Use
 

This gage has a polyimide carrier backing and a nickel-chrome element. Creep characteristics is much improved owing to its special grid pattern. This gage is used for measuring at high temperature up to 300°C

Main Test Materials Metal,Ceramic Materials Backing Polyimide
Operating Temperature -20 to +300°C Materials Element Ni-Cr alloy foil
Compensation range +10 to +100°C Strain limit 1%
(10000×10-6)
Bonding adhesive NP-50
CN,C-1
Fatigue life at room temp. 1×106
(±1500×10-6)

Gage pattern Type Gage
length
(mm)
Gage
width
(mm)
Backing
length
(mm)
Backing
width
(mm)
Resistance
(Ω)
Single element
(G.F. 2.1 approx.)

ZFLA-1-11 1 1.8 7 3 120
ZFLA-3-11 3 1.8 10.5 3.5 120
ZFLA-6-11 6 2.5 15.5 4.5 120
ZFLA-1•350-11 1 1.7 6.6 3.2 350
ZFLA-3•350-11 3 3.2 10.2 5.1 350
ZFLA-6•350-11 6 2.8 16 5.5 350
90° 2-element Cross
(G.F. 2.1 approx.)

ZFCA-1•350-11 1 1.7 8.5 8.5 350
ZFCA-3•350-11 3 1.4 10.5 10.5 350
45°/90°
3-element Rosette
(G.F. 2.1 approx.)

ZFRA-1•350-11 1 1.7 8.5 8.5 350
ZFRA-3•350-11 3 1.4 10.5 10.5 350

Site Map: Strain Gages, Strain Gage Series List, Integral Lead Wire Option, Strain Gage Adhesives, Coating Materials, Connection Terminals, Strain Gage Coding System, Theory of Strain Gages, Strain Gage Connections and Bridge Circuits, Load Cells, Displacement Tranducers, Pressure Transducers, Acceleration Transducers, Data Loggers/Static Strain meters, Dynamic Strainmeters, Histrogram Recorder, Indicators, Special Instrumentation, Related Instrumentation